Existing flat entrance fire doors do not automatically need replacing because they are older or lack modern certification. For leaseholders facing an unexpected bill, and managing agents deciding what work to commission, that distinction matters.
TL;DR
The government’s August 2025 guidance clarifies that missing certification, intumescent strips or smoke seals does not, by itself, make an older door unsuitable. Decisions should reflect its condition, adequacy and the building’s fire risk assessment. Routine checks and detailed assessments serve different purposes.

What did the government clarify?
On 8 August 2025, the government updated its fire door guidance following concerns that leaseholders had been advised to replace doors unnecessarily.
The guidance explains that the Fire Safety (England) Regulations 2022 do not require existing doors to meet today’s standards for new blocks.
A door that met the relevant standards when manufactured or installed may continue providing adequate protection, provided it remains undamaged and its gaps are appropriate. Its suitability still needs to be considered through the building’s fire risk assessment.
Does missing certification mean a door has failed?
Missing paperwork can create uncertainty, but it should lead to a properly explained assessment of the available evidence.
For anyone receiving a recommendation to replace a door, useful questions include:
- What specific problem has been identified?
- Does it affect the door’s ability to protect residents?
- What evidence supports the recommendation?
- Could suitable remedial work address the problem?
Our previous article on flat fire door regulations explains why a clear report should identify what has been found, why it matters and whether repair or replacement is recommended.
That gives leaseholders and building managers something concrete to act on, particularly when several doors within one block need attention.
What should a routine fire door check cover?
The government’s fire doors checklist covers the door, frame, surrounding wall, glazing, letterbox, hinges, locks, gaps and self-closing device.
It also includes strips and seals where present, alterations, damage and doors being wedged open.
Importantly, the checklist recognises that an older door without intumescent strips or smoke seals may be acceptable following consideration of fire risk. Where those components are fitted, their condition needs checking.
Recording the findings matters too. The checklist includes an action plan identifying the defect, proposed work, timescale and person responsible. This helps turn an observation into a repair that is actually completed, rather than an unresolved entry in a maintenance folder.
Is a routine check the same as a detailed survey?
No. The government’s Regulation 10 fact sheet explains that routine checks identify obvious damage and operational problems. They do not normally involve a detailed technical examination of fire resistance.
A specialist is not automatically required for these basic checks. However, concerns discovered during them may justify further investigation.
A detailed survey provides a closer examination of the installed doorset and supporting evidence. Through our fire door survey service, our sister company, MF Fire Door Inspections Limited, assesses installation, condition, certification and operation.
The findings provide recommendations that Metrix Contractors can use when undertaking necessary remedial work. This helps building managers understand the scope of work before arranging repairs or replacement.
How often must flat entrance doors be checked?
For multi-occupied residential buildings in England where the top storey is more than 11 metres above ground level, the Responsible Person must:
- Use best endeavours to check flat entrance fire doors at least every 12 months.
- Check fire doors within communal areas at least every three months.
These are separate duties, with different frequencies for different doors. Residents should also receive information explaining the importance of fire doors and their role in keeping the building safe.
Buildings below that height still have fire safety obligations. Relevant doors must provide adequate protection, and the Responsible Person’s wider duties under the Fire Safety Order continue to apply.

When is replacement the right decision?
An inspection identifying a defect does not automatically mean a complete replacement is required. Some problems can be corrected through suitable repairs, while others need replacement components or a new doorset.
As we explain in our fire door inspection article, that decision depends on the defect and the evidence available for the existing door.
Before approving work, ask for a clear written recommendation. It should explain the proposed solution and give the person commissioning it enough information to understand the decision.
Practical support from Metrix Contractors
At Metrix Contractors, we provide fire door installation and maintenance, alongside surveys delivered through MF Fire Door Inspections Limited.
If you are unsure whether existing flat entrance fire doors need attention, speak to us about your building and the findings you have received.
Call 01323 487134 or email info@metrixcontractors.co.uk to discuss the next steps.
1. Can I change the lock on my flat’s fire door?
Discuss lock changes with the building’s Responsible Person first. Alterations must preserve the door’s fire protection.
2. Can I add a letterbox to a flat entrance fire door?
Only after checking suitability. A new letterbox must be suitable for the fire door and fitted by a specialist contractor.
3. What if new carpet stops my fire door closing?
Report it promptly. The self-closer must shut the door fully without the door catching on flooring.
4. Can I remove the closer if my flat entrance door feels too heavy?
No. Report the problem and arrange assessment. Removing or disabling the closer compromises fire protection.
5. What happens if I cannot be home for a fire door check?
Ask your managing agent for another appointment. Where access cannot be obtained, the Responsible Person should record their attempts.
6. Does a fire door check require access inside my flat?
Yes. Flat entrance doors need checking on both sides, so access should be arranged with residents beforehand.
7. Do fire door rules apply to houses converted into flats?
Yes. Regulation 10 applies to converted buildings containing flats with shared escape routes, although scheduled checking duties depend on height.
8. How quickly should a faulty fire door be repaired?
Necessary repairs should be completed by a competent contractor as soon as reasonably practicable. Report faults promptly.
9. Can I wedge my flat entrance fire door open while bringing shopping in?
Keep the door shut when it is not in use. Remove any wedge immediately after access is finished.
10. Will adding smoke seals turn an ordinary front door into a fire door?
No. Seals alone cannot establish fire resistance. The complete door assembly needs assessment before any upgrade is recommended.